Description
APPA 605 | APPA 607 | |
Digital display | 4000 count | 10000Â count |
Analog Bar graph segments | 48 | 48 |
Auto Backlit, Dual Display | v | v |
Insulation Test Voltage 50V, 100V, 250V, 500V, 1000V | v | v |
Insulation Test Resistance up to 20.0GΩ | v | v |
Auto-discharge of capacitive voltage | v | v |
Min/Max | v | v |
Store/Recall Memories | v | v |
Low Pass Filter (High Frequency Rejection) | v | v |
Auto AC/DC Voltage detect | v | v |
Compare Function | v | N/A |
Earth Bond Resistance measurement | v | N/A |
PI/DAR | v | N/A |
Insulation test smooth testing | N/A | v |
Continuity | N/A | v |
Diode Test | N/A | v |
AC/DC mV | N/A | v |
AC/DC mA | N/A | v |
Frequency measurement | N/A | v |
Capacitance measurement | N/A | v |
Temperature measurement | N/A | v |
Temp. Adaptor & Bead Probe | N/A | v |
Remote Probe, Test Leads, Alligator Clips | v | v |
Automatic power shut off | v | v |
APPA 605 | APPA 607 | ||
DCV: | Ranges | 600.0V | 100.00mV ~ 1000.0V |
Resolution | 0.1V | 0.01mV | |
Basic Accuracy | ±(1.0%+5d) | ±(0.08%+2d) | |
Input Impedance | 3MΩ//<100pF | 10MΩ//<100pF | |
Overload Protection                                                                                                                                         00VDC | 600V AC rms or DC | 1000V AC rms or DC | |
ACV: | Ranges | 600.0V | 100.00mV ~ 1000.0V |
Resolution | 0.1V | 0.01mV | |
Basic Accuracy | ±(1.5%+5d) at 50Hz ~ 60Hz ±(2%+5d) at 60Hz ~ 500Hz |
±(0.9%+3d) at 50Hz ~ 60Hz ±(1.9%+3d) at 60Hz ~ 5kHz |
|
Input Impedance | 3MΩ//<100pF | 10MΩ//<100pF | |
Overload Protection                                                                                                                                         00VDC | 600V AC rms or DC | 1000V AC rms or DC | |
Conversion Type | True RMS | True RMS | |
DCA: | Ranges | N/A | 100.00mA, 400.0mA |
Resolution | 0.01mA | ||
Basic Accuracy | ±(0.2%+2d) | ||
Input Protection | 440mA/1000V DC/AC fuse | ||
ACA: | Ranges | N/A | 100.00mA, 400.0mA |
Resolution | 0.01mA | ||
Basic Accuracy | ±(1.5%+2d) at 50Hz ~ 5kHz | ||
Input Protection | 440mA/1000V DC/AC fuse | ||
Conversion Type | True RMS | ||
Earth Bond Resistance: | Ranges | 40.00Ω ~ 40.00kΩ | N/A |
Resolution | 0.1Ω | ||
Basic Accuracy | ±(1.5%+3d) | ||
Overload Protection                                                                                                                                         00VDC | 600V AC rms or DC | ||
Resistance: | Ranges | N/A | 1000.0 Ω ~ 40.00M Ω |
Resolution | 0.1Ω | ||
Basic Accuracy | ±(0.5%+2d) | ||
Overload Protection                                                                                                                                         00VDC | 1000V AC rms or DC | ||
Continuity Beeper: | Threshold | N/A | <30 Ω |
Diode Test: | Ranges | N/A | 2.000V |
Basic Accuracy | ±(0.5%+2d) | ||
Insulation Resistance: | Testing Voltage Ranges | 50V, 100V, 250V, 500V, 1000V | 50V, 100V, 250V, 500V, 1000V |
Resistance Ranges | 0.001M Ω ~ 20.0GΩ | 0.001M Ω ~ 20.0GΩ | |
Resolution | 1kΩ | 1kΩ | |
Basic Accuracy |  ±(1.5%+5d) |  ±(1.5%+5d) | |
Overload Protection                                                                                                                                         00VDC | 600V AC rms or DC | 600V AC rms or DC | |
Frequency Counter: | Ranges | NA | 100.00Hz ~ 100.00kHz |
Resolution | 0.01Hz | ||
Basic Accuracy |  ±(0.1%+5d) | ||
Overload Protection | 1000V AC rms or DC | ||
Capacitance: | Ranges | NA | 10.000nF~40.00mF |
Resolution | 0.001nF | ||
Basic Accuracy |  ±(1.2%+2d) | ||
Overload Protection | 1000V AC rms or DC | ||
Temperature: | Ranges | NA | -200℃ ~ 1200.0℃ |
Resolution | 0.1℃ | ||
Basic Accuracy | ± (1%+1℃ ) | ||
Overload Protection | 1000V AC rms or DC |
APPA 605 | APPA 607 | |
Sampling Rate | 3times/sec | 3times/sec |
Overload Indication: “OL” or “-OL” | v | v |
Low Battery Indication | ![]() |
|
Auto Power Off: Approx. 20 min. | v | v |
Operating Temperature: 0℃~50℃, ≦80%RH | v | v |
Storage Temperature: -20℃~60℃ | v | v |
Temperature Coefficient: 0.15(Spec.Acc)/℃, <18℃ or >28℃ | v | v |
Safety: IEC 61010-1 and designed to meet UL61010-1 specifications. Compliance to IEC61557. | CAT. IV 600V | CAT. IV 600V, CAT. III 1000V |
Power Requirement: AA size 1.5V x 4 batteries (NEDA 15A or IEC LR6) | v | v |
Battery Life: In hours ((Alkaline battery) | 1100 times of insulation tests | 80 |
Size: 95mm (W) x 200mm (L) x 51.20 mm (H), without holster | v | v |
Weight: In grams (with holster) | 630 | 630 |
Accessories:Â Remote Probe, Test Leads, Alligator Clips, Protective Holster, Magnetic Hanging Kit, Alkaline batteries (installed) and manual |
v | (Also included Temp. adaptor and bead probe) |
Specification subject to change without notice.
![](http://www.appatech.com/files/APPA-600-SERIES-d1.jpg)
DAY & NIGHT
An innovative auto ON/OFF backlit feature give you fulltime display visibility and increased battery life.
![](http://www.appatech.com/files/APPA-600-SERIES-d2.jpg)
INSULATION TESTING
Automatically measuring L, C and R with Q, D, and θ by just turn on the meter, …the firsst ever-smart LCR meter..
![](http://www.appatech.com/files/APPA-600-SERIES-d3.jpg)
CONVENIENT REPETITIVE TESTING
Ergonomically designed remote test probe for repetitive testing without pressing the TEST button on Tester/Meter for better convenience.
![](http://www.appatech.com/files/APPA-600-SERIES-d4.jpg)
LOW PASS FILTER (HIGH FREQUENCY REJECTION)
Bypass the noisy of electrical equipment for stable reading of measurement.
![](http://www.appatech.com/files/APPA-600-SERIES-d5.jpg)
EXTRA PROTECTION
Ergonomically designed slim shape protective holster that includes a built-in tilt stand, a nail hook, and convenient test lead storage. This holster provides an extra degree of protection and convenience for your meter.
![](http://www.appatech.com/files/APPA-600-SERIES-d6.jpg)
BATTERY & FUSE EASY TO REPLACE
Unscrew only one screw to remove battery door for battery replacement and fuse replacement, designed for user’s convenience without opening the bottom case.