Description
| APPA 201N | APPA 208 | APPA 208B | |
| Digital display | 2000 count | 4000/40000 count | 4000/40000 count | 
| Analog Bar graph Segments | N/A | 43 | 43 | 
| Autoranging and Manual selection | v | v | v | 
| AC+DC True RMS | AC only | v | v | 
| Auto Calibration | N/A | v | v | 
| Backlit | v | v | v | 
| Automatic AC/DC voltage detector with low impedance(Auto-V LoZ) | N/A | v | v | 
| High Frequency Rejection (HFR) | N/A | v | v | 
| Peak Hold | N/A | v | v | 
| Auto Hold | v | v | v | 
| MIN/MAX | v | v | v | 
| Relative Mode | N/A | v | v | 
| Duty Cycle | N/A | v | v | 
| Memory Store/Recall | N/A | 1000 | 1000 | 
| dBm/dB reading | N/A | v | v | 
| Data Logging Capacity | N/A | 40,000 | 40,000 | 
| Optical interface | N/A | v | v | 
| Bluetooth | N/A | N/A | v | 
| Auto fuse detection | N/A | v | v | 
| Beep Guard | N/A | v | v | 
| Low Battery Indication | v | v | v | 
| APPA 201N | APPA 208 | APPA 208B | ||
| DCV: | Ranges | 200mV to 600V | 40mV to 1000V | 40mV to 1000V | 
| Resolution | 100uV | 1uV | 1uV | |
| Basic Accuracy | ±(0.5%+2d) | ±(0.03%+10d) | ±(0.03%+10d) | |
| ACV: | Ranges | 200mV to 600V | 40mV to 1000V | 40mV to 1000V | 
| Resolution | 100uV | 1uV | 1uV | |
| Basic Accuracy | ±(1.5%+5d) | ±(0.5%+20d) | ±(0.5%+20d) | |
| Bandwidth | 50Hz to 500Hz | 40Hz to 100kHz | 40Hz to 100kHz | |
| (AC+DC)V: | Ranges & Resolution:Same as ACV, except Accuracy | N/A | v | v | 
| Auto V-LoZ | Range: 400.0V, 1000V | N/A | v | v | 
| DCA: | Ranges | 200uA to 10A | 40mA to 10A | 40mA to 10A | 
| Resolution | 0.1uA | 1uA | 1uA | |
| Basic Accuracy | ±(1.0%+2d) | ±(0.2%+10d) | ±(0.2%+10d) | |
| ACA: | Ranges | 200uA to 10A | 40mA to 10A | 40mA to 10A | 
| Resolution | 0.1uA | 1uA | 1uA | |
| Basic Accuracy | ±(1.5%+5d) | ±(0.8%+20d) | ±(0.8%+20d) | |
| Bandwidth | 50Hz to 500Hz | 40Hz to 10KHz | 40Hz to 10KHz | |
| (AC+DC)A: | Ranges & Resolution:Same as ACA, except Accuracy | N/A | v | v | 
| OHM: | Ranges | 200Ω to 20MΩ | 400Ω to 40MΩ | 400Ω to 40MΩ | 
| Resolution | 0.1Ω | 0.01Ω | 0.01Ω | |
| Basic Accuracy | ±(0.7%+3d) | ±(0.2%+10d) | ±(0.2%+10d) | |
| Continuity: | 2kHz Tone Buzzer | <50Ω | 10Ω~50Ω(Adj) | 10Ω~50Ω(Adj) | 
| Diode Test: | Open Circuit Voltage | ±3V | ±2.5V | ±2.5V | 
| Frequency Counter: | Ranges | 2000Hz to 20MHz | 40Hz to 4MHz | 40Hz to 4MHz | 
| Resolution | 1Hz | 0.001Hz | 0.001Hz | |
| Basic Accuracy | ±(0.01%+2d) | ±5d | ±5d | |
| Duty Factor: | Ranges | N/A | 5% to 95% | 5% to 95% | 
| Resolution | N/A | 0.1% | 0.1% | |
| Basic Accuracy:5Hz to 10kHz, 5Vp-p | N/A | ±3d | ±3d | |
| Capacitance: | Ranges | 2nF to 2mF | 40nF to 40mF | 40nF to 40mF | 
| Resolution | 1pF | 10pF | 10pF | |
| Basic Accuracy | ±(1.9%+8d) | ±(0.9%+2d) | ±(0.9%+2d) | |
| ℃ / ℉ | Ranges | N/A | -200℃ to 1200℃ | -200℃ to 1200℃ | 
| Resolution: | N/A | 0.1℃ | 0.1℃ | |
| Basic Accuracy: | N/A | ±(1%+10d) for ℃ | ±(1%+10d) for ℃ | 
| APPA 201N | APPA 208 | APPA 208B | |
| Analog bargraph display: | N/A | v | v | 
| Measuring Rate: | 1.5 times/sec | 10 times/sec | 10 times/sec | 
| Over range Indication : | OL | OL | OL | 
| Auto Power Off : | 10 minutes | 1~30 minutes(Adj) | 1~30 minutes(Adj) | 
| Operating Temperature : 0℃~50℃, ≦80%RH | v | v | v | 
| Storage Temperature : -20℃~60℃ | v | v | v | 
| Temperature Coefficient : 0.1 x (Spec.Acc)/℃, <18℃ or >28℃ | v | v | v | 
| Safety : IEC 1010-1 | CAT III 300V, CAT II 600V | CAT III 600V, CAT II 1000V | CAT III 600V, CAT II 1000V | 
| EMC: EN61326-1 | N/A | v | v | 
| Power Requirement:AC 100~ 240V, 50/60Hz, 10VA | v | v | v | 
| DC AA or LR6 or AM3 battery 1.5V x 6 | v | v | v | 
| Battery Life:In hours without backlight (Alkaline battery) | 1200 | 50 | 50 | 
| Size: without carrying case (mm) | 218(W) x 195(L) x 73(H) | 230(W) x 233(L) x 95(H) | 230(W) x 233(L) x 95(H) | 
| Weight:without power cord | 1.3Kg | 1.6Kg | 1.6Kg | 
| Accessories:Test Leads, carrying strap, power cord and manual | v | (also including Temp. probe, USB cable and APPA WinDMM 208 software) | (also including Temp. probe, USB cable and APPA WinDMM 208 software) | 
Specification subject to change without notice.

Designed for using in a laboratory

Designed for harsh environment

Extra back storage for full accessories

Handle carrying design for mobility